Leave Your Message
Products Categories
Featured Products

Anti-Vandal Corrosion-Proof Steel Footbridge per EN 1990, AASHTO LRFD & AS 5100

Product Positioning:Focused on lightweight steel pedestrian bridges for urban slow traffic systems, parks and scenic areas, school campuses, and river-crossing walkways, balancing safe passage with landscape aesthetics, offering both standardized and customized product solutions.

Core Advantages:Lightweight truss or plate beam structures combined with factory prefabrication allow on-site installation in just a few hours; the bridge deck integrates anti-slip, drainage, and lighting systems, achieving "finished at the factory, ready for use on site."

Global Compliance:Strictly meets mainstream international standards, including European standards (EN 1990 pedestrian load and EN 1993 steel bridge design), American standards (AASHTO LRFD pedestrian bridge sections and ADA accessibility regulations), and Australian standards (AS 5100 and DDA accessibility specifications).

Service Assurance:Provides one-stop technical support, from human-induced vibration comfort calculations, anti-slip grade selection, accessible ramp optimization, to on-site hoisting solutions and nighttime construction traffic organization design.

    Steel footbridges are a type of steel structure bridge specifically designed for pedestrians, bicycles, and light service vehicles. Their core characteristics are narrow bridge decks (1.2–4.0 meters), low live loads (4–5 kN/m²), but higher requirements for vibration comfort, slip safety, and architectural aesthetics. Unlike traditional highway steel bridges, the main design factor for pedestrian bridges is human subjective perception rather than ultimate load-bearing capacity. The products include various forms such as urban overpasses, park landscape bridges, campus corridors, and wetland boardwalks, and can adopt structural types such as trusses, plate girders, arch bridges, or cable-stayed bridges.

     

    93b6eff5eb1ba4caa41908e1c95e40e5

    1.Application Scenarios

    Application Scenarios

    Brief Description

    Urban Road Crossing

    Grade separation for pedestrian and vehicle traffic on main roads

    School & Campus Area

    Safe passage for students to avoid roadside traffic risks

    Park & Scenic Spot

    Landscape footbridge crossing lakes, streams and green belts

    Commercial Block

    Pedestrian passage connecting shopping areas and downtown blocks

    Residential Community

    Overpass connecting residential quarters and surrounding supporting facilities

     

    2.Product Highlights

    l Factory Pre-installation Rate of 98%: Rail posts, handrails, lighting channels, and anti-slip pavement are all completed in the factory. After on-site hoisting, the bridge is fully ready for use.

    l Adaptive Leveling Bearings: Beam ends are equipped with ±50mm height-adjustable bearings to accommodate construction height deviations of the bridge abutments, eliminating the need for on-site shimming or secondary casting.

    l Embedded Continuous Lighting: LED strips are embedded inside handrail tubes or the grooves of rail posts, providing even downward lighting at night, avoiding glare and preventing upward light pollution.

    l Full Accessibility Compatibility: The bridge deck is level with the adjacent ground or has a gentle 1:20 slope, with a clear width ≥1.8 meters, accommodating wheelchairs, strollers, and walkers.

    l Integrated Vibration-Damping TMD: For lightweight long bridges with a fundamental frequency near 2Hz, tuned mass dampers are hidden inside the handrail tubes to eliminate resonance induced by footsteps.

    l Bird-Repellent Design: The upper surface of truss members has a slope ≥45°, or stainless steel anti-bird spikes are added to prevent birds from resting and contaminating the bridge deck.

     

    94aa5ca1ca7e4ea36c817939c948c769

    3.Product Materials

    Ø Main Structural Profiles

    Closed square or round steel tubes (EU standard S355J2H / US standard ASTM A500 Gr.B / Australian standard AS 1163 C350), serving both structural load-bearing and architectural finishing functions.

    Ø Stainless Steel Railing System

    316L brushed stainless steel tubes, wall thickness 2.0–3.0mm, fully welded by argon arc welding, pickled and passivated with no visible weld seams; horizontal bar spacing ≤110mm to prevent children from slipping through.

    Ø Bridge Deck Paving System

    ² Outdoor: 3–5mm polyurethane anti-slip layer with wet-state slip resistance BPN ≥70, or hot-dip galvanized steel grating (40% open area for water permeability)

    ² Indoor: 2mm epoxy self-leveling quartz sand anti-slip texture, or anti-slip aluminum panels (embossed finish)

    Ø Fasteners

    All exposed bolts, nuts, and washers are A4-70 stainless steel, countersunk or semi-round head design to avoid protrusions that could injure pedestrians.

    Ø Downpipes and Drainage

    Hidden stainless steel downpipes routed through the interior of handrails to the side drainage channels of the bridge abutments, with no exposed pipes on the bridge deck.

    Ø Surface Treatment

    Main structure coated with automotive-grade metallic paint (full RAL color range) with epoxy zinc-rich primer (80% zinc content), epoxy micaceous iron oxide intermediate coat, and polyurethane topcoat, total film thickness ≥240μm, guaranteed 15 years without chalking or fading.

     

    701ffa7e551377d8342083c4d99eddd8

    4.Design Features

    ü Human-Induced Vibration Dominated Design: Fundamental frequency requirement ≥3 Hz (walking) or ≥5 Hz (running/jumping population) to avoid resonance with step frequency of 1.5–2.5 Hz; TMD or Tuned Liquid Dampers (TLD) can be added if necessary.

    ü Pedestrian Density Load Classification: Low-density scenario (<0.5 person/m²) uniform load 2.5 kPa; high-density scenario (>1.0 person/m², such as stadium aisles) uses 5.0 kPa with consideration of group synchronization effects.

    ü Barrier-Free Continuous Path: Height difference between any two points on the bridge deck ≤1:20, with rest platforms every 9 meters; tactile strips for the visually impaired set at start and end points and at turns.

    ü Drainage and Snow Prevention: Transverse slope ≥2%, continuous drainage channels at edges; in cold regions, electric heating strips can be installed under the deck to maintain surface snow melting temperature.

    ü Thermal Expansion and Contraction Movement Absorption: Expansion joints at bridge ends are covered in decorative strips, allowing ±20 mm temperature displacement, ensuring neat appearance.

    ü Redundant Fall Protection Design: Railings withstand horizontal loads ≥0.75 kN/m (EU standard) or 0.2 kip/ft (US standard), post spacing ≤1.5 meters, adjacent posts can still support load redistribution if any post fails.

     

    d2c0ae8da104e27baee268d3456bbb9f

    5.Core Advantages

    ⭐No Additional Load on Existing Structures: Self-weight only 15–30 kN (single 10-meter span), can be directly installed on existing walls or roofs without reinforcing the original structure.

    ⭐Factory Preassembly Eliminates On-Site Cutting: All components are cut, drilled, and welded to final dimensions in the factory; no cutting, welding, or fire hazards on site.

    ⭐Noise Reduction for Night Construction: Full bolted connection process allows quiet night construction near residential areas without impact or arc noise.

    ⭐Low Cost for Later Color Changes: Metal paint layer can be repainted according to surrounding building facade renovation plans without replacing railings or deck.

    ⭐Integrated Hidden Pipelines: Hollow railing posts serve as conduits for power and communication cables; lighting, broadcast, and monitoring lines are not exposed.

    ⭐Anti-Graffiti Surface Treatment: Fluorocarbon paint layer with oleophobic coating allows spray paint graffiti to be removed with solvents without affecting the underlying coating.

    ⭐Interchangeable Modules and Fewer Spare Parts: Bridge deck panels, railing units, and handrail pipes of the same project are fully interchangeable, reducing spare part inventory types by 70%.

     

    e4f52e00026b978d92574ba036ab1cc4

    6.Standard System

    Standard System

    Main Regulatory Code

    American Standard

    AASHTO Pedestrian Bridge, ASTM Carbon Steel Standard

    European Standard

    Eurocode 3, EN 1991 Pedestrian Load Regulation

    Chinese Standard

    JTG D64, GB 50017 Steel Structure Design Code

    Fabrication & Welding

    ISO 9001, AWS D1.2 Bridge Welding Standard

    Surface Protection

    ISO 12944 Coating and Atmospheric Corrosion Standard

     

    7.Why choose Us

    Choosing our steel footbridge means that you are choosing a design team that places "human experience" on the same level as "structural safety." We don't just deliver a bridge that can bear weight—we deliver gently sloped ramps that wheelchair users can navigate without assistance, tactile guidance that allows the visually impaired to perceive directions through foot textures, evenly distributed lighting that makes nighttime strollers feel safe, and a quiet walking experience that doesn't disturb surrounding residents with vibrations.

    📧Satisfied after reading? Feel free to contact us, we look forward to working with you!🤝