Leave Your Message
Products Categories
Featured Products

Corrosion-Resistant Grating Deck Panel to EN 1993, ASTM A709 & AS 5100

Product Positioning:Specially designed for new bridge construction and old bridge renovation projects, providing steel bridge decks that can be quickly installed. The range includes orthotropic steel decks (long lifespan), steel-concrete composite decks (high stiffness), and temporary steel grating decks (recyclable), suitable for different traffic volumes and construction schedules.

Core Advantages:Using closed U-ribs and high-strength steel top plates, fatigue resistance is improved by 50% compared to traditional open ribs; the waterproof layer and paving are pre-installed in the factory, allowing the bridge deck system to be completed immediately on site.

Global Compliance:Strictly compliant with mainstream international standards including European standards (EN 1993-1-5 local buckling of orthotropic decks and EN 1991-2 wheel load distribution), American standards (AASHTO LRFD Appendix B fatigue details and AWS D1.5 U-rib to top plate welds), and Australian standards (AS 5100.6 composite decks and AS 4100 thin plate stability).

Service Assurance:Provides full-cycle technical support, from fatigue grade verification of U-rib to top plate welds, analysis of collaborative deformation between paving layer and steel plate, integrated design of expansion joint slots, to on-site welding procedure evaluation and nondestructive testing solutions.

    A road bridge deck panel refers to the upper structural component that directly bears the wheel loads and transfers the loads to the main beams. Essentially, it is an orthotropic plate (with different longitudinal and transverse stiffness). Unlike traditional concrete slabs, steel bridge decks use thin steel plates combined with dense stiffening ribs to withstand tens of tons of wheel pressure with a thickness of only 15–20 mm. The products are divided into three types: open rib plates (convenient for maintenance), closed U-rib plates (excellent torsional resistance), and composite plates (with the greatest stiffness), which are one of the core technologies for lightweight steel bridges.

     

    469233e1444f5a9fd6f534ec1f22b83f

    1.Application Scenario

    Application Scenario

    Core Application

    New Bridge Construction & Overpass Build

    National trunk highways, intercity expressways, urban viaducts, interchanges, high-speed railway & light rail transit bridges

    Existing Bridge Rehabilitation & Capacity Expansion

    Aging bridge repair, damaged deck replacement, load capacity upgrade, highway lane expansion & traffic upgrading reconstruction

    Special Scenario Bridge Projects

    Pedestrian & landscape bridges, coastal high-salt, cold freeze-thaw, high-altitude, seismic zone bridges

    Temporary Bridge & Emergency Repair

    Disaster emergency repair, temporary construction access, event temporary traffic bridges

     

    2.Product Highlights

    l U-Rib Internal Welding Robot Construction: Uses an automatic walking cart to complete fillet welds on the inner side of U-ribs, upgrading the fatigue class from FAT 90 to FAT 125.

    l Asphalt Paving Without Bonding Layer: The top plate surface is rolled with 2mm deep diamond patterns, asphalt is directly laid, with a shear bonding strength ≥1.5 MPa.

    l Nitrogen Protection for Weld-Through Holes: Weld-through holes at the intersections of U-ribs and diaphragms are welded with nitrogen backing protection, forming a continuous oxide-free backside.

    l Magnetic Adsorption Temporary Fixing: Permanent magnetic suction cups are used for temporary fixing during the assembly of adjacent panels, replacing positioning welds and preventing base material damage.

    l Bolt-Clamped Plate Without Welded Connections: Adjacent panel joints are fixed with bolts and clamping plates, allowing the panel to be removed and replaced in whole without cutting or welding.

    l Long-Life Cold Zinc Spray Repair: On-site weld areas are repaired with cold zinc spray containing 96% zinc, compatible with the potential of hot-dip galvanized surfaces, preventing galvanic corrosion.

     

    b723e5f6ff981775c1495d46760883f2

    3.Product Materials

    ü Top Plate (Directly Bearing Wheel Load)

    European Standard S460M / S500M, American Standard A709 Gr.50W (weathering steel optional), Australian Standard AS 3597 Grade 500, thickness 12–20mm, upper surface can be rolled with 2mm deep diamond patterns to enhance bonding with the paving layer.

    ü U-Shaped Closed Stiffener (U Rib)

    European Standard S355J2 N (cold-formed), American Standard A572 Gr.50, Australian Standard AS/NZS 1594 HA350, thickness 6–8mm, opening width 250–300mm, height 80–120mm, spacing 300–600mm.

    ü Open Stiffener (Flat Steel or Angle Steel)

    European Standard S355J2 N, American Standard A36 / A572 Gr.50, Australian Standard AS 3678 Grade 300, height 80–120mm, thickness 10–14mm, suitable for scenarios requiring high maintenance convenience.

    ü Cross Panel (Solid Web or Truss Type)

    European Standard S355J2 N, American Standard A572 Gr.50, Australian Standard AS 3678 Grade 400, thickness 10–16mm, spacing 3–5m, with manhole openings (ø600mm) and U rib penetration openings (ø80–100mm).

    ü Shear Connectors (Composite Deck Slab)

    Stud material European Standard EN ISO 13918 (ML15), American Standard ASTM A29 (1015–1020 steel), Australian Standard AS 1391 Grade 1020, diameter 19–22mm, bending 45° after welding without cracks.

     

    beed80cc805832163089fd767b4d9043

    4.Design Features

    Ø Dual Load-Bearing System Separate Verification: The first system (overall deformation of the main beam) and the second system (local deformation under wheel load) are calculated separately and then superimposed.

    Ø U-Rib to Top Plate Weld Detail Optimization: Partial penetration groove fillet welds (penetration depth ≥75% of plate thickness), weld throat ≥5mm, weld leg size K ≥6mm.

    Ø Flexible Openings in Cross Beams: Ø80–100mm holes are made where U-ribs pass through the cross beam, with ring reinforcements or crescent-shaped reliefs at the edges of the holes.

    Ø Collaborative Design of Pavement Layer and Steel Plate: Top plate deflection controlled to L/1000 (second system) to ensure asphalt pavement does not develop reflective cracks.

    Ø Integrated Drainage Slope: Top plate transverse slope 2% (achieved via unequal U-rib heights or substrate), combined with drainage channels at the plate edges and downspouts.

    Ø Shear Connector Arrangement Clearance Zones: Weld studs in composite plates avoid U-rib locations and are arranged in the gaps between ribs at 150–300mm spacing.

     

    beed80cc805832163089fd767b4d9043

    5.Core Advantages

    ⭐Lowest Unit Area Weight: Closed U-rib plate (plate thickness 14mm, U-rib 8mm) only 90–120kg/m², which is 1/4–1/3 of concrete slabs.

    ⭐Most Predictable Fatigue Life: U-rib to top plate welds have been verified through millions of full-scale fatigue tests, and S-N curves are included in the code.

    ⭐Superior Under-Bridge Aesthetics: Perforated grille panels with 30–50% light transmittance, bright under the bridge with no sense of oppression.

    ⭐Excellent Adaptability to Extreme Elevations: Top plate transverse slope can be precisely controlled by adjusting U-rib height or pad thickness, ±2mm accuracy meets race track requirements.

    ⭐High Flexibility for Later Modifications: Bolt-connected press plate system allows individual panels to be removed for additional utilities or pavement replacement.

    ⭐Wide Climatic Adaptability: Top plate can be equipped with electric heating tapes or hot water circulation pipes, maintaining bridge deck temperatures above 5°C, completely eliminating ice and snow.

     

    f1f5e5080123adc98bc8a703d6d45f43

    6.Global Standard

    Standard Code

    Standard Name

    Issuing Organization

    Applicable Scope

    AASHTO LRFD BDS 9th Edition / ASTM A709/A709M-24 / ASTM C39/C39M-24

    LRFD Bridge Design Specifications / Structural Steel for Bridges / Concrete Compressive Strength Test

    American Association of State Highway and Transportation Officials (AASHTO) / American Society for Testing and Materials (ASTM)

    US highway bridge design, material performance & testing standards for global bridge engineering

    EN 1994-2:2005 / BS 5400-4:1990

    Eurocode 4: Composite Steel-Concrete Bridges / Concrete Bridges Design Code

    European Committee for Standardization (CEN) / British Standards Institution (BSI)

    EU & UK steel-concrete composite & concrete bridge deck design standards

    GB 50917-2013 / JTG/T 3364-2022 / TB 10091-2017

    Steel-Concrete Composite Bridges Design Code / Highway Bridge Deck Pavement Specification / Railway Bridge Steel Structure Design Code

    National Standardization Administration of China / Ministry of Transport of China / National Railway Administration of China

    Chinese highway, municipal & railway bridge design, construction & material standards

     

    7.Choose Us

    Choosing our road bridge deck panels means you are choosing a technical approach that increases the fatigue life of U-rib to deck welds from the million-cycle level to the ten-million-cycle level. We do not just deliver steel plates—we deliver stress envelopes verified through dual-system separate calculations, defect-free welds completed by internal welding robots, and a stiffness matching solution that allows the paving layer and steel plate to work together without cracking.

    📧Satisfied after reading? Feel free to contact us, we look forward to working with you!🤝

    f2dfc774f99c46a7772e6fde803c7e8a